General specifications | |
---|---|
Detection type | photoelectric sampling |
Pulse count | 1024 and 2048 |
Functional safety related parameters | |
Safety Integrity Level (SIL) | SIL 3 |
Performance level (PL) | PL e |
MTTFd | 709 a |
Mission Time (TM) | 10 a |
PFHd | 4.35 E-9 |
PFD | 3.1 E-5 |
L10h | 70 E+9 at 6000 rpm |
Diagnostic Coverage (DC) | 98.9 % |
Electrical specifications | |
Operating voltage | 5 V DC ± 5 % |
No-load supply current | max. 70 mA |
Output | |
Output type | sine / cosine |
Amplitude | 1 Vss ± 10 % |
Load current | max. per channel 10 mA , short-circuit protected, reverse polarity protected |
Output frequency | max. 200 kHz (3 dB limit) |
Connection | |
Cable | ?7.8 mm, 6 x 2 x 0.14 mm2, 1 m |
Standard conformity | |
Degree of protection | DINEN60529, IP65 |
Climatic testing | DINEN60068-2-78 , no moisture condensation |
Emitted interference | EN61000-6-4:2007/A1:2011 |
Noise immunity | DINEN61000-6-2 , advanced testing level to IEC61326-3-1 |
Shock resistance | DINEN60068-2-27, 100g, 3ms |
Vibration resistance | DINEN60068-2-6, 10g, 55...2000Hz |
Functional safety | IEC61508:2000 IEC62061:2005 ISO13849-1:2006 IEC61800-5-2:2007 EN50178:1997 IEC61326-3-1:2007 Suitable up to SIL 3, PL e depending from configuration, see manual and report |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
Ambient conditions | |
Operating temperature | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications | |
Material | |
Mass | approx. 350 g |
Rotational speed | max. 12000 min -1 |
Moment of inertia | ? 25 gcm2 |
Starting torque | ? 1.5 Ncm |
Shaft load |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |