Basic data | |||||||
---|---|---|---|---|---|---|---|
Series | RSL 400 | ||||||
Application | Mobile side guarding, Mobile danger zone guarding, Stationary access guarding, Stationary danger zone guarding | ||||||
Functions | |||||||
Functions | Resolution, selectable, Dynamic contactor monitoring (EDM), selectable, E-stop linkage, Four-field mode | ||||||
Characteristic parameters | |||||||
Type | 3, IEC/EN 61496 | ||||||
SIL | 2, IEC 61508 | ||||||
SILCL | 2, IEC/EN 62061 | ||||||
Performance Level (PL) | d, EN ISO 13849-1 | ||||||
PFHD | 9E-08 per hour | ||||||
Mission time | 20 years, EN ISO 13849-1 | ||||||
Category | 3, EN ISO 13849 | ||||||
Protective field data | |||||||
Scanning angle | 270 ° | ||||||
Minimum adjustable range | 50 mm | ||||||
Number of field pairs, reversible | 10 | ||||||
Number of quads, reversible | 10 | ||||||
Number of protective functions | 1 Piece(s) | ||||||
Number of independent sensor configurations | 1 | ||||||
Diffuse reflection, min. | 1.8 % | ||||||
Operating range | 0 ... 8.25 m | ||||||
Warning field data | |||||||
Number of field pairs | 10 | ||||||
Operating range | 0 ... 20 m | ||||||
Object size | 150 mm x 150 mm | ||||||
Diffuse reflection, min. | 10 % | ||||||
Optical data | |||||||
Light source | Laser, Infrared | ||||||
Laser light wavelength | 905 nm | ||||||
Laser class | 1, IEC/EN 60825-1:2007 | ||||||
Transmitted-signal shape | Pulsed | ||||||
Repetition frequency | 90 kHz | ||||||
Measurement data | |||||||
Distance resolution | 1 mm | ||||||
Detection range | 0 ... 50 m | ||||||
Diffuse reflection | 20 % | ||||||
Angular resolution | 0.1 ° | ||||||
Electrical data | |||||||
Protective circuit | Overvoltage protection | ||||||
Performance data | |||||||
Supply voltage UB | 24 V, DC, -30 ... 20 % | ||||||
Current consumption (without load), max. | 700 mA, (use power supply unit with 3 A) | ||||||
Power consumption, max. | 17 W, For 24 V, plus output load | ||||||
Protective circuit | Overvoltage protection | ||||||
Outputs | |||||||
Number of safety-related switching outputs (OSSDs) | 2 Piece(s) | ||||||
Safety-related switching outputs | |||||||
Type | Safety-related switching output OSSD | ||||||
Switching voltage high, min. | 20.8 V | ||||||
Switching voltage low, max. | 2 V | ||||||
Voltage type | DC | ||||||
Number of safety-related switching outputs (OSSDs) |